EasyManua.ls Logo

HP StorageWorks P9000 - Disk Arrays - [Maintenance] Correction Copy; [Maintenance] Drive Interrupt; [Maintenance] Format

HP StorageWorks P9000 - Disk Arrays
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed Information
DescriptionItem
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter (DKA), CM, MPB, or
ESW) to be blocked.
PCB
The number PCB to be blocked.Num. of PCBs
The mounting location of the PDEV (physical device) to be blocked.PDEV
The parity group number.PG
The number of parity groups.Num. of PGs
The LDEV number.LDEV
The number of LDEVs.Num. of LDEVs
[Maintenance] Correction Copy
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Correction Copy,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD00-01
Detailed Information
DescriptionItem
The mounting location of the PDEV (physical device).PDEV
[Maintenance] Drive Interrupt
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Drive Interrupt,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD00-01
Detailed Information
DescriptionItem
The mounting location of the PDEV (physical device).PDEV
[Maintenance] Format
The logged information indicates that the Format operation was only requested but not finished.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Format,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PG=[1-1],Num. of PGs=1
+PG=[E1-1],Num. of PGs=1 ->in case of an external volume
+PG=[V1-1],Num. of PGs=1 ->in case of a virtual volume
+PG=[X1-1],
Num. of PGs=1 ->in case of a Thin Provisioning volume
+LDEV=[0x00:0x03:0x2f],Num. of LDEVs=1
Maintenance Descriptions 85

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays