[Install] MP Install
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],MP Install,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Micro Program
={RAMBOOT,HTP,FCDG,DKCMAIN,DKAF},Num. of Kinds=5
+Target MP={MP00-1MA,MP01-1MA,MP02-1MA},Num. of MPs=3
Detailed Information
DescriptionItem
The kind of microcode installed.Micro Program
The number of kinds of the installed microcodes.Num. of Kinds
The mounting location of the installed processor.Target MP
The number of processors installed.Num. of MPs
[Install] M/F Cache Residency
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],M/F Cache Residency,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+LDKC:CU:LDEV=0x00:0x00:0x00
++{Define,Mode,Prestaging,Start CC-HH,End CC-HH}
=[{Set,Bind,No,00-00,00-10},
{Set,Priority,Yes,1000-00,1009-14}],
{Delete,-,-,1000-00,1009-14}],
Num. of Cache Residency Settings=3
Detailed Information
DescriptionItem
The LDKC number, the CU number, and the LDEV number of the logical volume (for a mainframe
system) where Cache Residency is set.
LDKC:CU:LDEV
The setting status of Cache Residency.
Set: set, Delete: cancel
Define
The setting mode of Cache Residency. Indicates a dash (-) when Define is Delete.
Bind: Bind mode, Priority: Priority mode
Mode
Indicates whether the Prestaging mode set is enabled or disabled. Indicates a dash (-) when
Define is Delete.
No: Prestaging mode is disabled, Yes: Prestaging mode is enabled
Prestaging
The starting cylinder number (CC) and the starting head number (HH) which the Cache Residency
is set or canceled.
Start CC-HH
The ending cylinder number (CC) and the ending head number (HH) which the Cache Residency
is set or canceled.
End CC-HH
The number of Cache Residency that has been set or canceled.Num. of Cache
Residency Settings
[Install] Cache Residency Prestaging 71

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals