Connector Connects to Pin no. Signal
JFUSES1
• Fuser
• Motor pins—1–4
• Thermistor—black wire 5–6
• Duplex sensor (S1)—7–9
• Thermistor—white wire 10–11
1 +24 V dc V_FUSER_PHA+ (doors closed)
2 +24 V dc V_FUSER_PHA– (doors closed)
3 +24 V dc V_FUSER_PHB+ (doors closed)
4 +24 V dc V_FUSER_PHB– (doors closed)
5 +2.3 V dc FUSER_HQ_THM
6 FUSER_HK_THM_RTN, ground
7 +5V_SW, +5 V dc
8 Ground
9 +3.3 V dc S1_MPF_SNS
10 +2.5 V dc BUR_THM
11 FUSER_BUR_THM_RTN, ground
12 Ground, (no wire)
JFPUSB1 Front panel USB N/A Not testable in field
JHVPS1 Developer/transfer HVPS 7 +3.3 V dc CMY_SRVO_OUT
10 +3.3 V dc ITM_SRVO_OUT
11 +3.3 V dc K_SRVO_OUT
13 +24 V dc
14 Ground
16 Ground
JHS1 FB home sensor 1 +5 V dc
2 Ground
JINT1 +5V safety interlock connector 1 +5 V dc VS_JINT–1
2 Ground
3 VS_INT, +5 V dc (door closed), 0 V dc (open)
JLCD1 Operator panel connector for CX410 and
CX510 models
N/A Not testable in the field