Learning Basic Features
94
Input Current (I2) Setting Details
Code
Description
IN-01 Freq at
100%
Configures the frequency reference for operation at the maximum current
(when IN-55 is set to 100%).
If IN-01 is set to 40.00, and default settings are used for IN-53–56, 20
mA input current (max) to I2 will produce a frequency reference of
40.00 Hz.
If IN-56 is set to 50.00, and default settings are used for IN-01 (60
Hz) and IN-5355, 20 mA input current (max) to I2 will produce a
frequency reference of 30.00 Hz (50% of 60 Hz).
IN-50 I2 Monitor
Used to monitor input current at I2.
IN-52 I2 Filter
Configures the time for the operation frequency to reach 63% of target
frequency based on the input current at I2.
IN-53 I2 Curr x1–
IN-56 I2 Perc y2
Configures the gradient level and off-set value of the output frequency.
[Gradient and off-set configuration based on output frequency]