225
Learning Advanced Features
The connection settings for Time Period and Time Event
There are 8 Time event modules in the Time Event function. The parameters for T-Events
1–8 are used to set the connections to each module for the Time Period and the Exception
Date. The parameters for T-Event 1–8 are used to specify the operation on particular days.
Each Time event module can be set for the connections to 4 Time period modules and 8
Exception days. Time event modules are set as a bit unit in the parameters for Events 1–8.
The diagram below shows the connections between the Time event modules and the time
period modules. The Time Event 1 is connected to Time Period 4. The Time Event 8 is
connected to Time Periods 1–4 and the Exception Dates 2.
Time Event Module Function Settings
The functions to be performed in the Time Event for T-Events 1–8 can be set. 30 functions
can be set (refer to page 220). There are 8 Time event modules in the Time Event. The
parameters for T-Events 18 are used to set the connections to each module for the Time
Period and the Exception Date. The parameters for T-Events 18 are used to specify the
operation on particular days.