EasyManua.ls Logo

Mazda Mazda6 - Page 143

Mazda Mazda6
909 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ON-BOARD DIAGNOSTIC
F155
F1
P0133 Front HO2S circuit malfunction ON 2
O
2
sensor
×
P0134
Front HO2S circuit no activity
detected
ON 2 CCM ×
P0138 Rear HO2S circuit high input ON 2 CCM ×
P0140
Rear HO2S circuit no activity
detected
ON 2 CCM ×
P0171 Fuel trim system too lean ON 2 Fuel ×
P0172 Fuel trim system too rich ON 2 Fuel ×
P0300 Random misfire detected Flash / ON 1 or 2 Misfire ×
P0301 Cylinder No.1 misfire detected Flash / ON 1 or 2 Misfire ×
P0302 Cylinder No.2 misfire detected Flash / ON 1 or 2 Misfire ×
P0303 Cylinder No.3 misfire detected Flash / ON 1 or 2 Misfire ×
P0304 Cylinder No.4 misfire detected Flash / ON 1 or 2 Misfire ×
P0327 Knock sensor circuit low input ON 1 CCM ×
P0328 Knock sensor circuit high input ON 1 CCM ×
P0335 CKP sensor circuit malfunction ON 1 CCM ×
P0340 CMP sensor circuit malfunction ON 1 CCM ×
P0403
EGR valve motor coils open or
short
ON 2 CCM ×
P0420
Catalyst system efficiency
below threshold
ON 2 Catalyst ×
P0443
Evaporative emission control
system purge control valve
circuit malfunction
ON 2 CCM ×
P0480
Fan relay control circuit
malfunction
OFF 2 Other ×
P0500
Vehicle speed sensor (VSS)
circuit malfunction (MTX)
ON 2 CCM ×
P0505 Idle control system malfunction OFF Other ——
P0506
Idle control system RPM lower
than expected
ON 2 CCM ×
P0507
Idle control system RPM higher
than expected
ON 2 CCM ×
P0511
Idle control system circuit
malfunction
ON 1 CCM ×
P0550 PSP switch circuit malfunction ON 2 CCM ×
P0602 PCM programming error ON 1 CCM ×
P0610
Control module vehicle options
error
ON 1 CCM ×
P0661 VIS control circuit low input OFF 2 Other ×
P0662 VIS control circuit high input OFF 2 Other ×
P0703 Brake switch input malfunction ON 2 CCM ×
P0704 Clutch switch input malfunction ON 2 CCM ×
P0850 Neutral switch input malfunction ON 2 CCM ×
P1410
Variable air duct valve circuit
malfunction
OFF 2 Other ×
P1562 PCM +BB voltage low ON 1 CCM ×
P2006
Variable tumble control system
shutter valve stuck closed
ON 2 CCM ×
P2009
Variable tumble control solenoid
valve circuit low input
ON 2 CCM ×
P2010
Variable tumble control solenoid
valve circuit high input
ON 2 CCM ×
P2228 BARO sensor circuit low input ON 1 CCM ×
P2229 BARO sensor circuit high input ON 1 CCM ×
P2502
Generator output voltage signal
no electricity
OFF 1 Other ——
P2503 Battery overcharge OFF 1 Other ——
DTC No. Condition MIL DC Monitor item
Memory
function
Page

Table of Contents

Related product manuals