F2
CALIBRATION RESISTOR INSPECTION
A6E404013050201
Note
• Perform the following test only when directed.
Resistance Inspection
1. Remove the calibration resistor.
2. Verify the calibration resistor rank number.
3. Refer to the table below and verify the resistance
corresponding to the resistor rank number.
4. Measure the resistance between the calibration
resistor terminals A and C using an ohmmeter.
• If not as specified, replace the calibration
resistor.
Specification
FUEL INJECTOR
CALIBRATION RESISTOR
RANK NUMBER
A6E40702056
A
B
C
D
A6E40702057
Fuel injector
rank number
Calibration resistor
Rank number Resistance (ohm)
1 1 30.9
2 2 41.2
3 3 53.6
4 4 68.1
5 5 84.5
66105
77130
88158
99196
10 10 243
11 11 301
12 12 365
13 13 442
14 14 549
15 15 665
16 16 825
17 17 1020
18 18 1240
19 19 1540
20 20 1920
21 21 2370
22 22 3010
23 23 4020
24 24 5760
25 25 9530
Fuel injector
rank number
Calibration resistor
Rank number Resistance (ohm)