F2158
ON-BOARD DIAGNOSTIC
DTC P0662
A6E407001082242
DTC P0662 VSC solenoid valve circuit high input
DETECTION
CONDITION
PCM monitors input voltage from VSC solenoid valve while engine is running. If input voltage from VSC
solenoid valve is above B+, PCM determines suction control valve circuit high input.
POSSIBLE
CAUSE
VSC solenoid valve malfunction
Connector or terminal malfunction
Short to power circuit in wiring between VSC solenoid valve terminal B and PCM terminal 101
PCM malfunction
A
B
VSC SOLENOID VALVE
A
B
101
101
PCM
4
2
2
3
5
VSC SOLENOID VALVE
HARNESS SIDE CONNECTOR
PCM CONTROL RELAY
TERMINAL C
PCM
HARNESS SIDE CONNECTOR