ON-BOARD DIAGNOSTIC
F2–155
F2
DTC P0606
A6E407001082239
Diagnostic procedure
End Of Sie
DTC P0610
A6E407001082240
Diagnostic procedure
End Of Sie
DTC P0606 PCM malfunction
DETECTION
CONDITION
• PCM does not read DTC from output devices.
POSSIBLE
CAUSE
• PCM internal malfunction
STEP INSPECTION ACTION
1
––
Replace PCM.
(See F2–64 PCM REMOVAL/INSTALLATION)
DTC P0610 Control module vehicle options error
DETECTION
CONDITION
• PCM data configuration error
POSSIBLE
CAUSE
• Configuration procedure has not been completed
• PCM malfunction
STEP INSPECTION ACTION
1 PERFORM DTC CONFIRMATION PROCEDURE
• Perform “DTC Confirmation Procedure”.
(See F2–85 DTC CONFIRMATION
PROCEDURE)
• Is same DTC present during KOEO or KOER
self-test?
Yes Perform “PCM Configuration Procedure”, then go to next
step.
(See F2–68 PCM CONFIGURATION)
No Intermittent concern exists. Go to “Intermittent Concern
Troubleshooting”.
(See F2–227 INTERMITTENT CONCERN
TROUBLESHOOTING)
2 VERIFY TROUBLESHOOTING OF DTC P0610
COMPLETED
• Make sure to reconnect all disconnected
connectors.
• Clear DTC from PCM memory using WDS or
equivalent.
• Perform KOEO/KOER self-test.
(See F2–86 KOEO/KOER SELF-TEST
PROCEDURE)
• Is same DTC present?
Yes Replace PCM, go to next step.
(See F2–64 PCM REMOVAL/INSTALLATION)
No Go to next step.
3 VERIFY AFTER REPAIR PROCEDURE
• Perform “After Repair Procedure”.
(See F2–86 AFTER REPAIR PROCEDURE)
• Is there any DTC present?
Yes Go to applicable DTC inspection.
(See F2–87 DTC TABLE)
No Troubleshooting completed.