18. Use a box spanner to install the valve insert in the heater body, and
tighten to a torque of 68 N∙m (50 lbf-ft).
19. Install the inlet tip in the heated body, and tighten to a torque of 61 N∙m
(45 lbf-ft).
20. Attach the gate seal and liner to the nozzle.
21. Attach the nozzle thermocouple.
17-18