NOTE
The following step is optional. It is required when there are actuation
connections within the plates.
16. Install the actuation connections into the bottom supply ports of the cylinder.
Pressure test the cooling connection. Make sure that there are no leaks.
In / out actuation lines from the plate
17. Install the termcon assembly, ground wire assembly, and thermocouple
assembly in the heated body.
Insert the end of the thermocouple fully into the mating hole and bend it
into the thermocouple groove.
2
1
3
1. Termcon assembly
2. Ground wire assembly
3. Thermocouple assembly