___________________________________________________________________________________
6 - 162 Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3 Electra Elite IPK II
Switch Settings
The CNF(16)-U20 ETU has the following switches.
J
DIP switch SW1
Refer to Table 6-58 CNF(16)-U20 ETU Dip Switch SW1. This
switch has four selector switches:
H
SW1-1 Restores ETU Port and /Modes settings to
Factory Default.
H
SW1-2 Defines either Simple or Advanced Mode.
H
SW1-3 Defines the 16 Port configuration.
H
SW1-4 Defines the 8 Port configuration.
J
RESET Switch SW2
This switch allows the technician to reset the CNF(16)-U20
ETU without having to remove and insert it again in the KTS.
J
Rotary Switch SW3
This switch is a 16-position (0~9,A~F) rotary switch to select
display options. Refer to Table 6-59 CNF(16)-U20 ETU Rotary
Switch SW3.
Table 6-58 CNF(16)-U20 ETU Dip Switch SW1
Multimedia ETU Port and Mode SW1-1 SW1-2 SW1-3 SW1-4
8-Port Simple Mode OFF ON OFF ON
16-Port Simple Mode OFF ON ON OFF
8-Port Advanced Mode OFF OFF OFF ON
16-Port Advanced Mode OFF OFF ON OFF
Table 6-59 CNF(16)-U20 ETU Rotary Switch SW3
Position
Channel Status Channel Status
0 CH8 (DS1) ON CH16 (DS1) OFF
0 CH7 (DS2) ON CH15 (DS2) OFF
0 CH6 (DS3) ON CH14 (DS3) OFF