4 Parameter List
4 - 18
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
*1 This setting is enabled when the 3G3AX-OP01 is connected.
*2 The default data was changed from the previous model.
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
A141 Calculation
Frequency
Selection 1
00: Digital Operator
01: Digital Operator (Volume
adjuster)
*1
02: Input FV (Voltage)
03: Input FI (Current)
04: Modbus communication
05: Option 1
06: Option 2
07: Pulse train frequency
02 Disabled Enabled 7-59
A142 Calculation
Frequency
Selection 2
03 Disabled Enabled
A143 Calculation
Function Operator
Selection
00: Addition (A141 + A142)
01: Subtraction (A141 – A142)
02: Multiplication (A141 x A142)
00 Disabled Enabled
A145 Frequency
Addition Amount
Setting
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz 7-60
A146 Frequency
Addition Sign
Selection
00: Frequency reference + A145
01: Frequency reference – A145
00 Disabled Enabled
A150 EL-S Shape
Acceleration
Curve Ratio 1
0. to 50.
10.
*2
Disabled Disabled % 7-57
A151 EL-S Shape
Acceleration
Curve Ratio 2
0. to 50.
10.
*2
Disabled Disabled %
A152 EL-S Shape
Deceleration
Curve Ratio 1
0. to 50.
10.
*2
Disabled Disabled %
A153 EL-S Shape
Deceleration
Curve Ratio 2
0. to 50.
10.
*2
Disabled Disabled %
Calculation frequency
Acceleration/Deceleration