4 Parameter List
4 - 22
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
*1 The default data was changed from the previous model.
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
b031 Soft Lock
Selection
00: Data other than b031 cannot
be changed when terminal
SFT is ON.
01: Data other than b031 and the
set frequency cannot be
changed when terminal SFT is
ON.
02: Data other than b031 cannot
be changed.
03: Data other than b031 and the
specified frequency parameter
cannot be changed.
10: Data can be changed during
RUN.
01 Disabled Enabled 7-75
b034 RUN Time/Power
ON Time
Detection Level
0: Disabled (Function not active)
1. to 9999. (0 to 9999)
1000 to 6553
(10000 to 65530)
0. Disabled Enabled 10 h 7-76
b035 RUN Direction
Limit Selection
00: No direction limit
01: Only Forward enabled
(Reverse limited)
02: Only Reverse enabled
(Forward limited)
00 Disabled Disabled 7-77
b036 Reduced Voltage
Startup Selection
0 (Reduced voltage startup time:
small) to 255 (Reduced voltage
startup time: large)
6 Disabled Enabled 7-77
b037 Display Selection 00: Complete display
01: Individual display of functions
02: User setting + b037
03: Data comparison display
04: Basic display
00
*1
Disabled Enabled 7-78
b038 Initial Screen
Selection
000: Screen on which the Enter
key was last pressed
001 to 010: d001 to d010
012 to 019: d012 to d019
022 to 030: d022 to d030
060: d060
201: F001
202: Do not set.
001 Disabled Enabled 7-81
b039 User Parameter
Automatic Setting
Function
00: Disabled
01: Enabled
00 Disabled Enabled 7-81
Lock
Others