4 - 27
4 Parameter List
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
4-3 Extended Function Mode
4
4-3-2 Group b: Detailed Function Parameters
*1 The default data was changed from the previous model.
b120 Brake Control
Function
Selection
00: Disabled
01: Enabled
00 Disabled Enabled 7-104
b121 Brake Release
Wait Time
0.00 to 5.00 0.00 Disabled Enabled s
b122 Acceleration Wait
Time on Brake
Control
0.00 to 5.00 0.00 Disabled Enabled s
b123 Stop Wait Time on
Brake Control
0.00 to 5.00 0.00 Disabled Enabled s
b124 Brake Error
Detection Time
0.00 to 5.00 0.00 Disabled Enabled s
b125 Brake Release
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz
b126 Brake Release
Current
0.00 to 2.00 x Rated current
(0.4 to 55 kW)
0.00 to 1.80 x Rated current
(75 to 132 kW)
Rated
current
value
Disabled Enabled
b127 Break Force
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz
b130 Overvoltage
Suppression
Function
Selection During
Deceleration
00: Disabled
01: Enabled (DC voltage kept
constant)
02: Enabled (Acceleration
enabled)
01
*1
Disabled Enabled 7-106
b131 Overvoltage
Suppression Level
During
Deceleration
200-V class: 330 to 390
400-V class: 660 to 780
380./760. Disabled Enabled V
b132 Overvoltage
Suppression
Parameter During
Deceleration
0.10 to 30.00 1.00 Disabled Enabled s
b133 Overvoltage
Suppression
Proportional Gain
During
Deceleration
0.00 to 2.55 0.50 Enabled Enabled
b134 Overvoltage
Suppression
Integral Time
During
Deceleration
0.000 to 9.999
10.00 to 65.53
0.060 Enabled Enabled s
b164 Initial Screen
Automatic Return
Function
00: Disabled
01: Enabled
00 Enabled Enabled 7-107
b166 Data Read/Write
Selection
00: R/W OK
01: R/W protected
00 Enabled Enabled 7-76
b180 Initialization
Execution
00: Function is disabled
01: Execute initialization
00 Disabled Disabled 7-95
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
Others