4 - 27
4 Parameter List
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
4-3 Extended Function Mode
4
4-3-2 Group b: Detailed Function Parameters
*1 The default data was changed from the previous model.
b120 Brake Control
Function
Selection
00: Disabled
01: Enabled
00 Disabled Enabled – 7-104
b121 Brake Release
Wait Time
0.00 to 5.00 0.00 Disabled Enabled s
b122 Acceleration Wait
Time on Brake
Control
0.00 to 5.00 0.00 Disabled Enabled s
b123 Stop Wait Time on
Brake Control
0.00 to 5.00 0.00 Disabled Enabled s
b124 Brake Error
Detection Time
0.00 to 5.00 0.00 Disabled Enabled s
b125 Brake Release
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz
b126 Brake Release
Current
0.00 to 2.00 x Rated current
(0.4 to 55 kW)
0.00 to 1.80 x Rated current
(75 to 132 kW)
Rated
current
value
Disabled Enabled –
b127 Break Force
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz
b130 Overvoltage
Suppression
Function
Selection During
Deceleration
00: Disabled
01: Enabled (DC voltage kept
constant)
02: Enabled (Acceleration
enabled)
01
*1
Disabled Enabled – 7-106
b131 Overvoltage
Suppression Level
During
Deceleration
200-V class: 330 to 390
400-V class: 660 to 780
380./760. Disabled Enabled V
b132 Overvoltage
Suppression
Parameter During
Deceleration
0.10 to 30.00 1.00 Disabled Enabled s
b133 Overvoltage
Suppression
Proportional Gain
During
Deceleration
0.00 to 2.55 0.50 Enabled Enabled –
b134 Overvoltage
Suppression
Integral Time
During
Deceleration
0.000 to 9.999
10.00 to 65.53
0.060 Enabled Enabled s
b164 Initial Screen
Automatic Return
Function
00: Disabled
01: Enabled
00 Enabled Enabled – 7-107
b166 Data Read/Write
Selection
00: R/W OK
01: R/W protected
00 Enabled Enabled – 7-76
b180 Initialization
Execution
00: Function is disabled
01: Execute initialization
00 Disabled Disabled – 7-95
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10