4 Parameter List
4 - 36
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
*1 The default data was changed from the previous model.
*2 Do not set.
C105 MP Gain Setting 50. to 200. 100. Enabled Enabled % 7-141
C106 AM Gain Setting 50. to 200. 100. Enabled Enabled % 7-144
C107 AMI Gain Setting 50. to 200. 100. Enabled Enabled %
C109 AM Bias Setting 0. to 100. 0. Enabled Enabled %
C110 AMI Bias Setting 0. to 100. 20. Enabled Enabled %
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
C111 Overload Warning
Level 2
0.0: Disabled Rated
current
value
Enabled Enabled A 7-74
Heavy
load
(CT)
0.00 to 2.00 x Rated
current (0.4 to 55 kW)
0.00 to 1.80 x Rated
current (75 to 132 kW)
Light
load
(VT)
0.00 to 1.50 x Rated
current (0.4 to 132 kW)
Rated
current
value
Enabled Enabled A
C121 FV Zero
Adjustment
0. to 9999.
1000 to 6553
(10000 to 65535)
Factory
default
Enabled Enabled – 7-24
C122 FI Zero
Adjustment
0. to 9999.
1000 to 6553
(10000 to 65535)
Factory
default
Enabled Enabled –
C123 FE Zero
Adjustment
0. to 9999.
1000 to 6553
(10000 to 65535)
Factory
default
Enabled Enabled –
C130 Multi-function
Output P1 ON
Delay Time
0.0 to 100.0 0.0 Disabled Enabled s 5-60
C131 Multi-function
Output P1 OFF
Delay Time
0.0 to 100.0 0.0
C132 Multi-function
Output P2 ON
Delay Time
0.0 to 100.0 0.0
C133 Multi-function
Output P2 OFF
Delay Time
0.0 to 100.0 0.0
C134 Multi-function
Output P3 ON
Delay Time
0.0 to 100.0 0.0
C135 Multi-function
Output P3 OFF
Delay Time
0.0 to 100.0 0.0
C136 Multi-function
Output P4 ON
Delay Time
0.0 to 100.0 0.0
C137 Multi-function
Output P4 OFF
Delay Time
0.0 to 100.0 0.0
C138 Multi-function
Output P5 ON
Delay Time
0.0 to 100.0 0.0
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10