4 Parameter List
4 - 38
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
*1 When 0 is set, the response time is 2 ms.
C153 Logic Output
Signal 4 Operator
Selection
00: AND
01: OR
02: XOR
00 Disabled Enabled – 7-132
C154
Logic Output Signal
5 Selection 1
Same as options for C021 to C026
(33 (LOG1), 34 (LOG2), 35
(LOG3), 36 (LOG4), 37 (LOG5),
38 (LOG6), 63 (OPO), and no
(NO) cannot be selected)
00
C155
Logic Output Signal
5 Selection 2
Same as options for C021 to C026
(33 (LOG1), 34 (LOG2), 35
(LOG3), 36 (LOG4), 37 (LOG5),
38 (LOG6), 63 (OPO), and no
(NO) cannot be selected)
00
C156 Logic Output
Signal 5 Operator
Selection
00: AND
01: OR
02: XOR
00
C157
Logic Output Signal
6 Selection 1
Same as options for C021 to C026
(33 (LOG1), 34 (LOG2), 35
(LOG3), 36 (LOG4), 37 (LOG5),
38 (LOG6), 63 (OPO), and no
(NO) cannot be selected)
00
C158
Logic Output Signal
6 Selection 2
Same as options for C021 to C026
(33 (LOG1), 34 (LOG2), 35
(LOG3), 36 (LOG4), 37 (LOG5),
38 (LOG6), 63 (OPO), and no
(NO) cannot be selected)
00
C159 Logic Output
Signal 6 Operator
Selection
00: AND
01: OR
02: XOR
00
C160
Multi-function Input
S1 Response Time
0. to 200. (x 2 ms)
*1
1. Disabled Enabled ms 7-140
C161
Multi-function Input
S2 Response Time
0. to 200. (x 2 ms)
*1
1.
C162 Multi-function
Input S3
Response Time
0. to 200. (x 2 ms)
*1
1.
C163 Multi-function
Input S4
Response Time
0. to 200. (x 2 ms)
*1
1.
C164 Multi-function
Input S5
Response Time
0. to 200. (x 2 ms)
*1
1.
C165 Multi-function
Input S6
Response Time
0. to 200. (x 2 ms)
*1
1.
C166 Multi-function
Input S7
Response Time
0. to 200. (x 2 ms)
*1
1.
C167
Multi-function
Input S8
Response Time
0. to 200. (x 2 ms)
*1
1.
C168 Forward RUN
Command FW
Response Time
0. to 200. (x 2 ms)
*1
1.
C169
Multi-step Speed/Position
Determination Time
0. to 200. (x 10 ms)
*1
0. Disabled Enabled ms 6-40
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal