5 Basic Settings
5 - 26
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
The frequency reference methods that are used generally are shown below.
Set the frequency reference via the volume adjuster for frequency setting on the Digital Operator
(Model: 3G3AX-OP01).
*1 This setting is enabled when the 3G3AX-OP01 is connected.
Set a frequency reference in the Output Frequency Setting/Monitor (F001) or 1st/2nd/3rd Multi-step
Speed Reference 0 (A020/A220/A320) via the built-in digital operator or the optional LCD Digital
Operator.
Using Digital Operator (Volume Adjuster)
Parameter No. Function name Data
Default
data
Unit
A001 Frequency
Reference Selection
00:
Digital Operator (Volume adjuster)
*1
02 –
Using Digital Operator
Parameter No. Function name Data
Default
data
Unit
A001
Frequency
Reference Selection
02: Digital Operator (F001)
02 –