EasyManua.ls Logo

Omron RX Series - Page 275

Omron RX Series
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 - 7
6 Vector Control
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
6-2 Sensorless Vector Control
6
6-2-3 Auto-tuning of Motor Parameters
2
Selection of motor rotation during auto-tuning
In the Auto-tuning Selection (H001), select whether the motor rotates during auto-tuning.
3
Auto-tuning
(1) After presetting of parameters, set the Auto-tuning Selection (H001) to 01 (Enabled:
No motor rotation) or 02 (Enabled: Motor rotation).
(2) Turn ON the RUN command.
Turning ON the RUN command starts automatic operation in the following
procedure.
Parameter
No.
Function name Data Default data Unit
H003/H203 1st/2nd Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/
4.0/5.5/7.5/11.0/15.0/18.5/22/30/37/45/
55/75/90/110/132
Maximum
applicable
motor capacity
kW
H004/H204
1st/2nd Motor Pole
Number
2/4/6/8/10 4 pole
A003/A203 1st/2nd Base Frequency
30. to 1st/2nd Maximum Frequency
(A004/A204)
60 Hz
A045 Output Voltage Gain 20. to 100. 100. %
A051
DC Injection Braking
Selection
00: Disabled
01: Enabled
02: Enabled (Operates only at set
frequency)
00
A082
Motor Rated Voltage
Selection
200-V class: 200 V/215 V/220 V/230 V/
240 V
200
V
400-V class: 380 V/400 V/415 V/440 V/
460 V/480 V
400
Set value Description
01 The motor does not rotate during auto-tuning.
02 The motor rotates during auto-tuning.
Motor rotation
selection
Description
Motor does not
rotate (01)
Measures motor parameter values without rotating the motor. Use this setting if
you do not rotate the motor. Because the motor does not rotate, the Motor
Parameter Io (No-load current) and Motor Parameter J (Moment of inertia)
values cannot be measured.
Motor rotates (02)
Measures motor parameter values with the motor rotating. Use this setting if you
can rotate the motor without any problem.
Parameter No. Function name Data Default data Unit
H001 Auto-tuning Selection
00: Disabled
01: Enabled (No motor rotation)
02: Enabled (Motor rotation)
00

Table of Contents

Related product manuals