6 Vector Control
6 - 42
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
*2 The reset function does not initialize the internal data including position control settings.
Parameter
No.
Function name Data Default data Unit
d030 Current Position Monitor
–268435455 to 268435455
(P012 = 02)
–1073741823 to 1073741823
(P012 = 03)
(Displays MSB 4 digits including “–”)
––
C001 to
C008
Multi-function Input S1 to
S8 Selection
45: ORT (Orientation)
54: SON (Servo ON)
66: CP1 (Position command selection 1)
67: CP2 (Position command selection 2)
68: CP3 (Position command selection 3)
69: ORL (Zero return limit signal)
70: ORG (Zero return startup signal)
71: FOT (Forward driving stop)
72: ROT (Reverse driving stop)
73: SPD (Speed/Position switching)
––
C021 to
C025
Multi-function Output P1
to P5 Selection
22: DSE (Excessive speed deviation)
23: POK (Reverse driving stop)
C026
Multi-function Relay
Output (MA, MB) Function
Selection
C102 Reset Selection
03: Trip reset only
*2
02 –