7 - 25
7 Detailed Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
7-3 Basic Functions (Group A)
7
Adjustments for FE-FC Terminals
Parameter No. Function name Data Default data Unit
A111 FE Start Frequency –400. to –100.
–99.9 to –00.0
0.00 to 99.99
100. to 400.
(Set start and end frequencies.)
*1
*1. The inverter operates at –10 to 10 V when both A111 and A112 are set to 0.00.
0.00 Hz
A112 FE End Frequency
A113 FE Start Ratio
–100. to FE End Ratio
(Set a start ratio relative to an external
frequency reference of –10 to 10 V)
*2
*2. The ratio relative to an external frequency reference of –10 to 10 V is as follows.
· –10 to 0 V: –100% to 0%
· 0 to 10 V: 0% to 100%
For example, to use an external frequency reference of –5 to 5 V between the FE and FC terminals, set A113 to
–50% and A114 to 50%.
0.
%
A114 FE End Ratio
FE Start Ratio to 100.
(Set an end ratio relative to an external
frequency reference of –10 to 10 V)
*2
100.
Related functions A005, A006, C001 to C008, C081, C082