EasyManua.ls Logo

Omron RX Series - Page 543

Omron RX Series
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 - 67
8 Communications Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
8-5 Modbus Communication Register Number List
8
8-5-4 Group A/b/C/H/P Register List
1634 to
1638 hex
1633 hex Not used
1639 hex 1638 hex Pulse Train Frequency Scale P055 R/W
10 to 500
* Input frequency at maximum
frequency
0.1 [kHz]
163A hex 1639 hex
Pulse Train Frequency Filter
Time Parameter
P056 R/W 1 to 200 0.01 [s]
163B hex 163A hex
Pulse Train Frequency Bias
Amount
P057 R/W –100 to 100 1 [%]
163C hex 163B hex Pulse Train Frequency Limit P058 R/W 0 to 100 1 [%]
163D hex 163C hex Not used
163E hex 163D hex
Multi-step Position Command 0
P060
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
163F hex 163E hex
P060
(LOW)
R/W
1640 hex 163F hex
Multi-step Position Command 1
P061
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
1641 hex 1640 hex
P061
(LOW)
R/W
1642 hex 1641 hex
Multi-step Position Command 2
P062
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
1643 hex 1642 hex
P062
(LOW)
R/W
1644 hex 1643 hex
Multi-step Position Command 3
P063
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
1645 hex 1644 hex
P063
(LOW)
R/W
1646 hex 1645 hex
Multi-step Position Command 4
P064
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
1647 hex 1646 hex
P064
(LOW)
R/W
1648 hex 1647 hex
Multi-step Position Command 5
P065
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
1649 hex 1648 hex
P065
(LOW)
R/W
164A hex 1649 hex
Multi-step Position Command 6
P066
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
164B hex 164A hex
P066
(LOW)
R/W
164C hex 164B hex
Multi-step Position Command 7
P067
(HIGH)
R/W
Position range specification
(reverse side) to position range
specification (forward side)
1
164D hex 164C hex
P067
(LOW)
R/W
164E hex 164D hex Origin Search Mode P068 R/W
00: Origin search mode 1
01: Origin search mode 2
02: Origin search mode 3
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution

Table of Contents

Related product manuals