Performing internal logging
ZW-7000/5000 
User's Manual
109
 3 
Basic Operation
When the number of loggings reaches 2,000,000, past logging data is overwritten and logging continues 
on the latest data.
2
Set the output conditions of internal logging data.
Set the conditions for the external output using the non-procedural command LO.
Item Setting item Setting value Description
Internal logging 
setting
Output data 
format
ASCII (default value)/
Binary
Select the output format for outputting internal logging data.
For the response format of LO commands according to the output data format, refer to following page.
“5-1 Connecting by No-protocol Communications” described in Displacement Sensor ZW-7000/
5000 series Confocal Fiber Type Displacement Sensor User’s Manual for Communications Settings 
(Z363)