Setting Sensing
ZW-7000/5000 
User's Manual
211
Sensor controller operations
7
Setting Area follow
Area Followp.123
As an example, here is an explanation of the procedure for setting the upper line and lower line of the following 
edge t
o follow the reference edge.
Operating procedure
Steps Key operation Display Description
1
Press and hold the  key for two seconds to enter the FUNC 
mode.
2
Press the  /  keys to select “SENS” and press the  key.
3
Press the  /  keys to select “FOLLOW” and press the   
key.
4
Press the  /  keys to select “MOdE” and press the   
key.
5
Set the Area mode.
1.MODE: 1 Area mode
2.MODE: 2 Area mode
Current setting value is displayed on the sub-display.
Press  /  key to enter editing mode and the sub-display blinks.
In this example, select “2.MODE” and press the 
key.
6
Press the  key for two seconds to enter the RUN mode.
To save the setting, refer to "7-2 Functions of Operating Keys" 
(p.197).