Setting the Output Conditions
ZW-7000/5000
User's Manual
217
Sensor controller operations
7
7-8 Setting the Output Conditions
Setting the Filter
Setting Filters p.136
Setting the Median Filter
Setting the Median Filter p.137
As an example, here is an explanation of the procedure for selecting the “5” median filter setting.
Operating procedure
Steps Key operation Display Description
1 Press and hold the key for two seconds to enter the FUNC
mode.
2 Press the / key to select MEAS, then press the key.
3 Press the / keys to select “TASK1” and press the
key.
4 Press the / keys to select “FILTER” and press the
key.
5 Select “MEDIAN” as the filter type.
Press the / keys to select “MEDIAN” and press the
key.
6 Select the filter mode from the following:
OFF / 3 / 5 / 9 / 15 / 31
The current setting value is displayed on the sub-display.
Press / key to enter editing mode and the sub-display blinks.
In this example, select “5” and press the
key.
7 Press the key for two seconds to enter the RUN mode.