EasyManua.ls Logo

Omron ZW-7000 Series - Perform the Zero Reset

Omron ZW-7000 Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Switching operation modes
90
ZW-7000/5000
User's Manual
3-2 Switching operation modes
The Sensor Controller has two operation modes. One is RUN mode/Setup mode and the other is FUNC mode.
Switch to the desired mode depending on purpose.
(The Sensor Controller always starts up in the RUN mode when the power is turned on.)
Multi-view explorer : [Device Group] | [(Sensor Name)] (double click)
Edit pane : [Online] icon ( )
When operating the Sysmac Studio, regardless of its operation mode (RUN or Setup), always set the operation
mode of the Sensor Controller to RUN.
Item Setting item Mode Description
Online Operation mode RUN Switches to RUN (operation) mode. Normal operation mode.
FUNC Switches to FUNC mode. Mode for setting the measurement conditions.
1
Select the operation mode with [Operation
mode].
The operation mode of the Sensor Controller can be switched only with a key operation.
7-4 Switching operation modes p.199
Important
Note

Table of Contents

Related product manuals