Performing internal logging
106
ZW-7000/5000
User's Manual
3-8 Performing internal logging
Up to 2000000 data of measurement values can be logged in the Sensor Controller's internal memory.
Internal logging can be started or ended using Sysmac Studio, parallel I/O, or non-procedural communications
commands.
Th
e operating procedures for each method are shown below.
The settings that can be enabled for each method are shown below.
Internal logging by Sysmac Studio
Data logging conditions and logging start/end timing can be set with Sysmac Studio.
Multi view Explore : [(ZW model name)] (double click)
→ Edit pane : [Online] icon ( )
→ Online setting window : [Internal Logging]
Function Sysmac Studio Parallel I/O Non-procedural commu-
nications commands
Specify start timing Press the "Logging Start" button. LOGGING input ON Send LS command
Specify end timing Stops automatically after the specified
number of logging data has been saved.
LOGGING input OFF Send LE command
Output logging data Press the "Save to file (Sensor → PC)"
button.
Send LO/LG
command
Send LO/LG command
Clear logging data Cleared automatically after the "Logging
Start" button is pressed.
Send LC command Send LC command
Function Sysmac Studio Parallel I/O Non-procedural commu-
nications commands
Overwrite mode OFF ON/OFF ON/OFF
Label insert mode OFF ON/OFF ON/OFF
Output data format ASCII ASCII/Binary ASCII/Binary
1
Set the logging conditions.
Enter the [Data interval], [Number of logging
data],
and select the stored output data.