Setting the Output Conditions
152
ZW-7000/5000
User's Manual
Setting the Zero Reset
Setting the Status
Set enable/disable of the zero reset function.
The status is set for each task.
Multi View Explore : [Bank] | [(Bank Data Name)] (double click)
→ Edit pane : [Task Settings] icon ( )
→ Task Settings window : [Zero reset]
3
Enter [Delay time] and [Sampling time].
Set so that the “delay time + sampling time” is
shorter than the TIMING input interval. When the
TIMING input turns ON again before the “delay
time + sampling time” elapses, the TIMING input
that is input later is ignored and is not reflected in
sampling.
The trigger delay can also be set by the oper
ating ke
ys on the Sensor Controller.
Setting a Trigger Delay p.228
Item Setting item Setting value Description
Zero reset Status OFF
ON (default value)
Turn Zero reset ON/OFF.
1
Select ON/OFF from [Status].
The status can also be set by the operating keys on the Sensor Controller.
Setting the Status p.230