Setting the Output Conditions
ZW-7000/5000
User's Manual
151
4
Settings for Function
Setting a Trigger Delay
Set this to ignore measure values following TIMING input to avoid the influence of bounding or mechanical
vibration when a device is started up.
The delay time (the delay between timing input and the start of sampling) and the sampling time can be set.
Multi View Explore : [Bank] | [(Bank Data Name)] (double click)
Edit pane : [Task Settings] icon ( )
Task Settings window : [Hold]
Item Setting item Setting value Description
Trigger delay Trigger delay mode OFF (default value)/ON Turns the trigger delay ON/OFF.
Delay time Internal synchronous measurement
mode
0.02(default value) to 5000[ms]
Sets the period(time) between when turns ON
TIMING input and
starts sampling.
External/PDO synchronous measure-
ment mode
1(default value) to 50000[count]
Measures the measuring count between when turns
ON TIMI
NG input and sta
rts sampling.
Sampling time Internal synchronous measurement
mode
0.02 to 5000[ms]
100(default value)
Set the time when perform the sampling.
External/PDO synchronous measure-
ment mode
1(default value) to 50000[count]
Set the measuring count when performs sampling.
1
Set the hold mode and trigger.
Setting the Hold Mode p.144
Setting Triggers p.147
2
Check the check box in [Trigger delay]-
[Trigger delay mode].
ON
OFF
Measured values in this time period
is included in the sampling.
Delay time Sampling time
TIMING input
Sampling period
Measured value