Setting the System
246
ZW-7000/5000
User's Manual
Setting the Synchronous Measurement Mode
Setting Measurement Mode of the Sensor p.88
Operating procedure
For more detail, refer to the following.
7-1 Connecting Parallel I/O in Confocal Fiber Type Displacement Sensor.
Steps Key operation Display Description
1 Press and hold the key for two seconds to enter the FUNC
mode.
2 Press the / keys to select “SYSTEM” and press the
key.
3 Press the / keys to select “TRIGER” and press the
key.
4 Select the Trigger mode.
AUTO: Internal synchronous measurement mode
PARA.IN: External synchronous measurement mode
ECT.PDO: PDO synchronous measurement mode
The current settings are displayed on the sub digital.
Press the / keys to enter the editing mode, and the sub-
display blinks.
In this example, select “PARA.IN” and press the
key.
5 Press the key for two seconds to enter the RUN mode.
For how to save settings, refer to 7-2 Functions of Operating Keys
p.197.