Setting Measurement Items
ZW-7000/5000 
User's Manual
127
 4 
Settings for Function
Measuring the Thickness
If you have glass of known thickness, scaling can be adjusted referenced to that glass so that transparent 
objects can be measured more easily.
 Multi View Explorer : [Bank] | [(Bank Data Name)] (double click) 
→ Edit pane : [Task Settings] icon ( ) 
→ Task Settings window : [Measurement mode]
• When the measurement surface setting is set to Peak for thickness measurement, the measurement may become 
unstable depending on the incident level on each surface. Change the measurement surface setting for each 
surface from Peak to 1/2/3/4.
• With the above procedure, the same area surface must be set f
or Measur
ement surface 1 and Measurement 
surface 2. Therefore, to set different area surfaces for Measurement surface 1 and Measurement surface 2, set the 
height measurement of each surface to two tasks and calculate the difference.
Item Setting item Setting value Description
Thickness 
settings
Measurement 
surface 1
Edge1/Edge2/Edge3/Edge4/ 
Peak (default value)
The measurement surface (top surface) targeted for 
measurement can be switched.
The peak is the surface of all measurement
 surfaces having 
the highest received light amount.
Measurement 
surface 2
Edge
1/Edge2 /Edge3/Edge4/ 
Peak (default value)
The measurement surface (rear surface) targeted for 
measurement can be switched.
The peak is the surface of all measurement
 surfaces having 
the highest received light amount.
1
Select [Thickness] in [Measurement mode].
2
Select the measurement surface (top 
surface) targeted for measurement from 
[Measurement surface 1].
3
Select the measurement surface (rear 
surface) targeted for measurement from 
[Measurement surface 2].
Sensor head
Transparent 
object
Edge 1st
Edge 2nd
Thickness
Important