Setting Sensing
ZW-7000/5000
User's Manual
123
4
Settings for Function
Area Follow
When using the 2 area mode, by setting the reference edge and following edge, the measurement area of Area
2 can be automatically set to follow the workpiece even when it vibrates.
Below are examples of when the reference edge is set as the 1st edge and the following edge is set as the 2nd edge.
l When the workpiece is near the measurement center
l When the workpiece is on the NEAR side
l When the workpiece is on the FAR side
Area 1
Area 2
Area 1
Area 2
Transparent workpiece
Using the 1st edge as a
reference, the Area 2
measurement area is
automatically set so that only
the 2nd edge is included.
Area 1
Area 2
After Area 2 is automatically
set, even if the workpiece
vibrates, Area 2 moves to follow
the workpiece using the 1st
edge as a reference.
This allows the 2nd edge to be
acquired with the optimum
setting.