Loading...
Installation
64
ZW-7000/5000
User's Manual
l
ZW-5000 Series
Extension fiber cable (option)
Connecting adapter (option)
Handling fiber cables
Use them in compliance with the following. This may result in damage to the fiber cable.
- Fiber cable bend radiuses must be at least 20 mm.
- Do not yank hard on a fiber cable.
- Do not step on a fiber cable or place anything heavy on it.
Model Length
ZW-XF5002R 2 m
ZW-XF5005R 5 m
ZW-XF5010R 10m
ZW-XF5020R 20m
ZW-XF5030R 30m
Model
ZW-XFC2
Extension fiber cable
ZW-XF50 @@R
 (2m/5m/10m/20m/30m
Sensor Head
fiber cable
Connection adaptor
ZW-XFC2
Convex section
Mate the convex section of the fiber cable with the groove
on the connection adapter and turn the threaded section
clockwise while pushing in.
In the "No good" status in figure below, optic signals cannot
be transmitted and correct measurement is not possible.
Always check that the system is in the "Good" status.
Groove
Important