the chassis can be extended into the service position and returned to the
rack position without interference from the cables.
10 Slide the chassis into the rack position and into the service position several
times to ensure that the chassis can be extended into the service position
without interference from the cables.
Caution: If the cables become snagged while the chassis is extended into
the service position, damage to the motherboard might occur.
Related Links
Cabling Workow
Pilot Cabling
Routing Cables
Pilot Management Interface Wiring Diagram
Connect the Cables to Controller 1
1 Slide Controller 1 into the service position.
2 Connect the power cords with C13-to-C14 straight connectors to the power
supplies on Controller 1 and route the power cords through the cable
management arm (CMA).
3 Connect the end of the cable labeled “CU1 NET 3” to the the NET 3 port on
Controller 1 and route the cable through the CMA.
Note: The other end of this cable was connected to the NET 1 port on the
Pilot when you cabled the Pilot.
4 Connect the end of the cable labeled “CU 1 NET 2” to the NET 2 port on
Controller 1 and route the cable through the cable management arm
(CMA).
5 Connect the end of the cable labeled “CU1 NET MGT” to the NET MGT
port on Controller 1 and route the cable through the CMA.
6 Connect the end of the cable labeled “CU 1 <- - ->” to the cluster
interconnect network port on Controller 1 and route the cable through the
CMA.
7 Spool any unconnected ends of the cables in a logical manner and use
Velcro to aach the spools to a temporary location on the rack rail.
Aaching the spooled ends of the cables to the rack rail provides a
temporary strain relief to reduce the amount of stress on the cable
connectors and ports. Make sure to leave enough cable slack to ensure that
the chassis can be extended into the service position and returned to the
rack position without interference from the cables.
8 Slide the chassis into the rack position and into the service position several
times to ensure that the chassis can be extended into the service position
without interference from the cables.
Connect the Internal Cables
143

Table of Contents

Other manuals for Oracle FS1-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle FS1-2 and is the answer not in the manual?

Oracle FS1-2 Specifications

General IconGeneral
BrandOracle
ModelFS1-2
CategoryStorage
LanguageEnglish

Related product manuals