Tip: Ensure that you have all of the parts in the Controller rail kit before you
begin the installation of the Controller rails on the rack and the Controller
chassis.
Note: To locate part numbers for the rail kits, open Oracle System Handbook
(hps://support.oracle.com/handbook_private/index.html) and go to the
Oracle FS1 Flash Storage System components list. Part numbers are listed in the
components list.
Install the Rack Rails for the Controller
Prior to adding Controllers, install rails into the rack for each Controller that you
plan to add.
Prerequisites:
• Ensure that you have adequate room to work around the rack while
installing the rails and the Controller.
• Aach an electrostatic discharge (ESD) wrist strap to your wrist, and stand
on an ESD mat while replacing components.
• Ensure that you have a Phillips Number 2 screwdriver with at least a 4-inch
shaft.
• If you are installing the rails in a rack with threaded holes, make sure you
have a Torx Number 20 screwdriver.
1 Mark the rack mount hole where you plan to mount the Controller.
The Controller requires two standard rack units (2U) of vertical space.
2 Remove the rails from the packaging.
3 Position the front of the left rail behind the left front rack rail.
Install Component Rails
48

Table of Contents

Other manuals for Oracle FS1-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle FS1-2 and is the answer not in the manual?

Oracle FS1-2 Specifications

General IconGeneral
BrandOracle
ModelFS1-2
CategoryStorage
LanguageEnglish

Related product manuals