Table 45: Drive Enclosure LED status and description (power cooling module)
Status Status
indicator
(green)
Fan fail indicator
(amber)
AC fail indicator
(amber)
DC fail indicator
(amber)
AC power is not
available on
either power
cooling module.
O
O O O
AC power is not
available on this
power cooling
module.
O
O On On
AC power is
present, and the
status of the
power cooling
module is normal.
On
O O O
The power
cooling module
fan is outside of
acceptable limits.
O
On O O
The power
cooling module
fan failed.
O On O O
A fault is present
(over
temperature, over
volts, over
current).
O
On On On
The power
cooling module is
in standby mode.
Flashing O O O
The power
cooling module is
downloading
rmware.
O
Flashing Flashing Flashing
Oracle FS System LED Status
206