Caution: Be sure to maintain reliable grounding of racked equipment. Give
particular aention to supply connections other than direct connections to the
branch circuit, such as connections to power strips.
1 Review the Oracle FS System power requirements.
2 Review the information about power cabling and verify that your PDUs
meet the electrical requirements.
3 Route the power cables securely. Routing and securing power cables
within the rack is essential to prevent damage due to loose or overhanging
cables. Routing the cables is also required for easy access and servicing of
the Oracle FS System components (Pilots, Controllers, and Drive
Enclosures).
Note: The power cables connecting the Oracle FS System to the main
power supply in the data center are routed based on whether the source of
the main power supply in the data center is located overhead or located at
the oor level.
4 Secure the power cables to the rack such that they do not restrict the
removal of any other component.
Important: Do not connect the PDUs to external power circuits until the
installation is complete and all internal cables are in place.
Power On the System
Set up a separate circuit and power outlet for each power distribution unit (PDU)
as part of your site planning. These outlets must be located within reach of the
PDU power cables.
Caution: Do not turn on any power circuits until the installation of all ordered
hardware is complete and all internal cables are in place. Turning on the power
to the system prematurely can prevent the system from starting up correctly.
1 Ensure that the PDU circuit breaker switches are in the “OFF” or “O”
position.
2 Connect the PDUs to the power source at the data center.
If the main circuit breakers at the data center are powered o, turn them on
to supply power to the PDUs.
3 Ensure that the power switches on the Drive Enclosures are switched on.
System Power
154

Table of Contents

Other manuals for Oracle FS1-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle FS1-2 and is the answer not in the manual?

Oracle FS1-2 Specifications

General IconGeneral
BrandOracle
ModelFS1-2
CategoryStorage
LanguageEnglish

Related product manuals