Note: You can select any Drive Enclosure from the list. To ensure expedient
rebuild times, perform a drive failure test on the highest-tier Drive
Enclosure in the system.
5 From the I/O Module list, select 0 or 1, and click Next.
A large amount of data displays in the Drive Enclosure Console. To
conrm that the console commands succeed, copy and paste the
information into a text editor and review the information in the text editor.
6 From the View Drive Enclosure Console command eld, type SCSI and
click Send.
7 Type CHK and click Send.
The console displays a list of the drives installed on the Drive Enclosure.
The following example shows a list of drives displayed in the console.
Note: If any of the drives are oine, select a dierent Drive Enclosure.
8 Type ATA and click Send.
9 Type FPOFF XX, where XX is the number from the Drv column for one of
the drives displayed in the console output.
10 Click Send.
The drive fails from both nodes. Use the GUI to conrm the status of the
drive.
11 To bring the drive back online, type FPON XX, where XX is the number from
the Drv column for the drive displayed in the console, and click Send.
The drive returns online. Use the GUI to conrm the status of the drive.
Complete the Installation