D = Water pump
E = Delivery pipe to cylinder
F = By-Pass pipe
G = Thermostat
H = Radiator delivery pipe
TECHNICAL SPECIFICATIONS
Specification Desc./Quantity
Cooling system capacity: ~ 2 l
Recommended fluid AGIP PERMANENT SPEZIAL (ready for use)
Sealing pressure Cap calibrated at 0.9 bar
THERMOSTAT
Specification Desc./Quantity
Type Wax-type, with deviator
Starts opening at 85 ± 2°C
ELECTRIC VENTILATION
Specification Desc./Quantity
Electric ventilation starts at 100° C
Electric ventilation stops at 90° C
WATER PUMP
Specification
Desc./Quantity
Type Centrifugal
Control Electric, commanded by the control unit
RADIATOR
Specification
Desc./Quantity
Type Aluminium, with horizontal circulation
EXPANSION TANK
Specification
Desc./Quantity
Calibration Automatic bleeding, in parallel with the radiator
Electric fan check
- Check and, if necessary, restore the correct battery voltage.
Characteristic
Battery voltage
12V
Beverly 300 i.e. Cooling system
COOL SYS - 247