Chapter 5 Maintaining Your Library
Maintenance Actions
Scalar i2000 User’s Guide 254
The Teach dialog box appears.
Configure is already selected by default.
4 Click Start.
During the configuration teach process, the picker moves to each storage
magazine, I/E magazine, and drive in the library and stores information
about them. Teach results appear in the Results text box when the process
completes. If the configuration teach process completes successfully, the
Teach dialog box could close automatically.
Running Calibration Teach 5
Starting the calibration teach process causes the library to assess the
position and alignment of various library components through the use of
calibration targets. Use this process to avoid cartridge-handling problems
caused by rack, drive, or I/E station misalignments.
Rack alignment calibration targets are tabs that are located on two special
magazines in each drive-side and door-side storage rack. I/E station
targets are small square holes that are located at the top and bottom of the
I/E station. Whenever you perform work on the library that could affect
the position of rack, drive, or I/E station calibration targets, even slightly,
you should initiate the calibration teach process.
If the physical library is not offline, you receive a
message that asks you whether you want to take it
offline. Click Yes.