R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT Command Reference
SCPI Command Reference
Operating Manual 1145.1084.12 – 30 1068
Device-specific, command or query
SYSTem:PRESet:USER[:STATe] <Boolean>
Activates or deactivates the User Preset File specified using
SYSTem:PRESet:USER:NAME '<Setup_file>'.
If the User Preset File cannot be accessed (e.g. because it was deleted or moved) or cannot be loaded
(e.g. because it contains mismatching frequency converter settings), the Factory Preset is used as a fall-
back.
When activated, the selected User Preset File defines the default settings for MEMory:DEFine
'<setup_name>' and manual Preset (via GUI or front panel key). *RST and SYSTem:PRESet only use
it if SYSTem:PRESet:REMote[:STATe] is set to ON.
OFF - User Preset File inactive (factory preset is used)
ON - User Preset File active
– (*RST does not affect the preset state setting)
Device-specific, command or query
SYST:PRES:USER:NAME 'C:\Program Files\Rohde&Schwarz\Network
Analyzer\RecallSets\Setup_2.zvx'
Select a setup file for the user-defined preset.
SYST:PRES:USER ON
Enable a user-defined preset.
Press System – Preset (manual control) or use
MEM:DEF 'My Setup'
Alternative setting:
SYSTem:PRESet:REMote ON; *RST
Align *RST to the user-defined preset and carry out the user-defined preset.
SYSTem:PRESet:USER:NAME '<Setup_file>'
Specifies the setup file that will be used as User Preset File if SYSTem:PRESet:USER[:STATe] is ON.
String parameter to specify the name and directory of the setup file to be loaded.
The default extension (manual control) for setup files is *.zvx, although other
extensions are allowed. If no path is specified the analyzer searches the default
directory (subdirectory ...RecallSets)
– (*RST does not affect the preset settings)
Device-specific, command or query