RL78/G1H CHAPTER 14 SERIAL ARRAY UNIT
R01UH0575EJ0120 Rev. 1.20 Page 398 of 920
Dec 22, 2016
(3) Processing flow (in single-transmission/reception mode)
Figure 14 - 66 Timing Chart of Slave Transmission/Reception (in Single-Transmission/Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
Reception & shift operation
Reception & shift operation
Reception & shift operation
SSmn
SEmn
SDRmn
STmn
SCKp pin
SIp pin
Shift
register mn
INTCSIp
TSFmn
SOp pin
Data transmission/receptionData transmission/receptionData transmission/reception
Transmit data 3Transmit data 2Transmit data 1
Receive data 3Receive data 2Receive data 1
Transmit data 3Transmit data 2Transmit data 1
Receive data 1
Receive data 2
Receive data 3
Write
Read
Read
WriteWrite
Read

Table of Contents