RL78/G1H CHAPTER 8 TIMER RJ
R01UH0575EJ0120 Rev. 1.20 Page 223 of 920
Dec 22, 2016
CHAPTER 8 TIMER RJ
8.1 Functions of Timer RJ
Timer RJ is a 16-bit timer.
This 16-bit timer consists of a reload register and a down counter. The reload register and the down counter are
allocated to the same address, and they can be accessed by accessing the TRJ0 register.
Table 8 - 1 lists the Timer RJ Specifications. Figure 8 - 1 shows the Timer RJ Block Diagram.
Table 8 - 1 Timer RJ Specifications
Item Description
Operating modes Timer mode The count source is counted.
Count source (Operating clock) f
CLK, fCLK/2, fCLK/8, fIL, fSUB, or event input from the event link controller (ELC)
selectable
Interrupt When the counter underflows.
Selectable functions Coordination with the event link controller (ELC).
Event input from the ELC is selectable as a count source.