SERVICE PROGRAM MODE 26 July 2002
5-36
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Access code
1 Password Registers/changes the password for the key operator.
[0 ∼ 99999999 / 0 / 1 /step]
“0” indicates no code has been registered. SP7-810 can
be used to clear the key operator password.
409
2 Access Area Decides which programs require key operator codes.
[0 ∼ 2 / 0 / 1 /step]
• 0: None
• 1: Some key operator user tool settings
• 2: All user tool programs
PM Alarm
1 PM Alarm Level
501
2 Original Count Alarm
Specifies the PM alarm level.
[0 ∼ 255 / 0 / 1 /step]
• 0: Disables the PM alarm
• 1
∼
255: Specifies the PM alarm level.
The PM alarm occurs when L x 1000 >= C, where L is
the specified level and C is the current PM counter
value.
Jam alarm Japan Only
1 Jam Alarm Selects the jam alarm level.
[0 ∼ 3 / 3 / 1 /step]
• 0: Z (none)
• 1: L (6K x 1/4)
• 2: M (6K x 1/2)
• 3: H (6K)
504
2 Error Alarm
Enables/disables the control call when an unremoved
jam occurs.
[0 ∼ 1 / 0 / 1 /step]
• 0: Disabled
• 1: Enabled
An “unremoved jam” is a paper jam that remains
unremoved for 15 minutes. If 1 is selected, the machine
beeps if an unremoved jam has occurred.
Error Alarm Japan Only
505
1 Error Alarm
[0 ∼ 255 / 40 / 1 /step]
Supply Alarm Japan Only
1 Paper Supply Alarm
2 Staple Supply Alarm
3 Toner Supply Alarm
Turns the supply alarm on or off.
[0 ∼ 1 / 0 / 1 /step]
• 0: Off • 1: On
128 Interval: Others
132 Interval: A3
133 Interval: A4
134 Interval: A5
141 Interval: B4
142 Interval: B5
160 Interval: DLT
164 Interval: LG
166 Interval: LT
507
172 Interval: HLT
The machine issues the control call when the number of
paper sheets reaches the specified value.
[00250 ∼ 10000 / 1000 / 1 sheet/step]