Remote Control
R&S
®
FSVA/FSV
678Operating Manual 1176.7510.02 ─ 09
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation[:STATe].......................................... 682
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks[:IMMediate].............................................. 682
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:ANNotation:LABel:STATe.......................... 683
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:COUNt?...................................................683
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:LIST:SIZE................................................ 684
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:SEAR:AUTO............................................ 684
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:SORT...................................................... 684
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:STAT.......................................................685
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:X.............................................................685
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:Y?........................................................... 686
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:RESult?...................................................686
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE............................... 687
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe]...................................................687
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown............................................................ 688
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown:FREQuency?........................................689
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown:QFACtor...............................................689
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown:RESult?............................................... 690
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown:STATe................................................. 690
CALCulate<n>:MARKer<m>:FUNCtion:NDBDown:TIME?..................................................691
CALCulate<n>:MARKer<m>:FUNCtion:NOISe[:STATe].....................................................691
CALCulate<n>:MARKer<m>:FUNCtion:NOISe:RESult.......................................................692
CALCulate<n>:MARKer<m>:FUNCtion:REFerence...........................................................692
CALCulate<n>:MARKer<m>:FUNCtion:TOI:RESult?......................................................... 693
CALCulate<n>:MARKer<m>:FUNCtion:TOI:SEARchsignal ONCE...................................... 693
CALCulate<n>:MARKer<m>:FUNCtion:TOI[:STATe]......................................................... 693
CALCulate<n>:MARKer<m>:FUNCtion:ZOOM..................................................................694
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE <Mode>
This command selects the way the results for a band power marker are displayed.
Suffix:
<n>
.
irrelevant
<m> irrelevant
Parameters:
<Mode> POWer
Result is displayed as a power in dBm.
DENSity
Result is displayed as a density in dBm/Hz.
*RST: POW
Example:
CALC:MARK:FUNC:BPOW:MODE DENS
Manual operation: See "Power" on page 295
See "Density" on page 295
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
This command queries the results of the band power measurement.
Remote Control – Commands