Remote Control
R&S
®
FSVA/FSV
815Operating Manual 1176.7510.02 ─ 09
[SENSe:]LIST:RANGe<range>[:FREQuency]:STARt......................................................... 817
[SENSe:]LIST:RANGe<range>[:FREQuency]:STOP..........................................................817
[SENSe:]LIST:RANGe<range>:FILTer:TYPE.................................................................... 818
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation............................................................818
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation:AUTO..................................................819
[SENSe:]LIST:RANGe<range>:INPut:GAIN:STATe........................................................... 819
[SENSe:]LIST:RANGe<range>:LIMit:STARt......................................................................819
[SENSe:]LIST:RANGe<range>:LIMit:STATe..................................................................... 820
[SENSe:]LIST:RANGe<range>:LIMit:STOP...................................................................... 820
[SENSe:]LIST:RANGe<range>:POINts.............................................................................820
[SENSe:]LIST:RANGe<range>:RLEVel............................................................................ 821
[SENSe:]LIST:RANGe<range>:SWEep:TIME................................................................... 821
[SENSe:]LIST:RANGe<range>:SWEep:TIME:AUTO..........................................................821
[SENSe:]LIST:RANGe<range>:TRANsducer.....................................................................822
[SENSe:]LIST:RANGe<range>:BANDwidth[:RESolution] <Value>
This command sets the RBW value for the specified range.
Suffix:
<range>
.
1...20
range
Parameters:
<Value> Refer to the data sheet.
*RST: 30.0 kHz
Example:
LIST:RANG2:BAND:RES 5000
Sets the RBW for range 2 to 5 kHz.
Manual operation: See "RBW" on page 379
[SENSe:]LIST:RANGe<range>:BANDwidth:VIDeo
This command sets the VBW value for the specified range.
Suffix:
<range>
.
1...20
range
Parameters:
<Value> Refer to the data sheet.
*RST: 10.0 MHz
Example:
LIST:RANG1:BAND:VID 5000000
Sets the VBW for range 1 to 5 MHz.
Manual operation: See "VBW" on page 379
[SENSe:]LIST:RANGe<range>:BREak <State>
This command configures the sweep behavior.
Remote Control – Commands