Remote control commands
R&S
®
SMB100B
492User Manual 1178.3711.02 ─ 08
[:SOURce<hw>]:POWer:ALC:MODE?..............................................................................492
[:SOURce<hw>]:POWer:ALC[:STATe].............................................................................. 492
[:SOURce<hw>]:POWer:ALC:DSENsitivity....................................................................... 493
[:SOURce<hw>]:POWer:ALC:SONCe.............................................................................. 493
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE......................................................... 493
[:SOURce<hw>]:POWer:EMF:STATe................................................................................494
[:SOURce<hw>]:POWer:LBEHaviour............................................................................... 494
[:SOURce<hw>]:POWer:LIMit[:AMPLitude].......................................................................494
[:SOURce<hw>]:POWer:MANual.....................................................................................495
[:SOURce<hw>]:POWer:MODE.......................................................................................495
[:SOURce<hw>]:POWer:POWer......................................................................................496
[:SOURce<hw>]:POWer:STARt....................................................................................... 496
[:SOURce<hw>]:POWer:STOP........................................................................................496
[:SOURce<hw>]:POWer:STEP:MODE............................................................................. 497
[:SOURce<hw>]:POWer:STEP[:INCRement].................................................................... 497
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet........................................................ 497
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL............................................................. 498
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]..................................................498
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:REFLevel..................................................... 499
[:SOURce<hw>]:POWer:RANGe:LOWer?........................................................................ 499
[:SOURce<hw>]:POWer:RANGe:UPPer?.........................................................................499
[:SOURce]:POWer:WIGNore...........................................................................................500
[:SOURce<hw>]:POWer:ALC:MODE?
Queries the currently set ALC mode.
See [:SOURce<hw>]:POWer:ALC[:STATe] on page 492.
Return values:
<PowAlcMode> 0 | AUTO | 1 | PRESet | OFFTable | ON | OFF | ONSample |
ONTable
Example:
POW:ALC:MODE?
Response: ONTable"Table and On" is set automatically.
Usage: Query only
[:SOURce<hw>]:POWer:ALC[:STATe] <State>
Parameters:
<State> 0 | OFF | AUTO | 1 | ON | ONTable | PRESet | OFFTable
AUTO
Adjusts the output level to the operating conditions automati-
cally.
1|ON
Activates internal level control permanently.
OFFTable
Controls the level using attenuation values of the internal ALC
table.