Remote Control Commands
R&S
®
SMBV100A
614Operating Manual 1176.8016.02 ─ 17
Example:
BB:ARB:TRIG:OUTP2:PULS:DIV 4
sets the divider for the marker signal on the output to the value
4.
BB:ARB:TRIG:OUTP2:MODE PULS
enables the pulsed marker signal.
BB:ARB:TRIG:OUTP2:PULS:FREQ?
queries the pulse frequency of the marker signal.
Response: 33 000
the resulting pulse frequency is 33 kHz.
Usage: Query only
Manual operation: See "Marker Mode" on page 401
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut:DELay:FIXed <Fixed>
The command restricts the marker delay setting range to the dynamic range. In this
range the delay can be set without restarting the marker and signal. If a delay is
entered in setting ON but is outside this range, the maximum possible delay is set and
an error message is output.
The setting always affects every marker.
Parameters:
<Fixed> 0 | 1 | OFF | ON
*RST: 0
Example:
BB:ARB:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
Manual operation: See "Fix marker delay to current range " on page 402
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay <Delay>
Sets the delay between the signal on the marker outputs and the start of the signals.
Parameters:
<Delay> float
Range: 0 to depends on other values
Increment: 0.001
*RST: 0
Default unit: Symbol
Example:
BB:ARB:TRIG:OUTP2:DEL 16
sets a delay for the signal on connector MARKER 2.
Manual operation: See "Marker x Delay" on page 401
SOURce Subsystem