Instrument Function
R&S
®
SMBV100A
401Operating Manual 1176.8016.02 ─ 17
Marker Mode
Provides the settings necessary to define the marker output signal for synchronizing
external instruments.
Marker Mode
Marker configuration for up to 4 marker channels. The settings are used to select the
marker mode defining the shape and periodicity of the markers. The contents of the
dialog change with the selected marker mode; the settings are self-explanatory.
Note: The marker trace in the waveform file remains unchanged. It is not overwritten,
even if something else than "Unchanged" has been selected.
All regular marker signals are described in "Marker Modes" on page 336.
"Unchanged"
The marker signal remains unchanged as defined in the waveform
file.
"Restart"
A marker signal is generated at the start of each ARB sequence.
This marker mode is not enabled for muti segment waveforms.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:MODE on page 611
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:DIVider
on page 613
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:FREQuency?
on page 613
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern on page 613
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:OFFTime on page 612
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:ONTime on page 612
Marker Delay
The delay of the signals on the MARKER outputs is set in the"Marker Delay" section.
Marker x Delay
Enters the delay between the marker signal at the marker outputs and the start of the
frame or slot.
The input is expressed as a number of symbols. If the setting "Fix marker delay to
dynamic range" is enabled, the setting range is restricted to the dynamic range. In this
range the delay of the marker signals can be set without restarting the marker and sig-
nal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay on page 614
Current Range without Recalculation
Displays the dynamic range within which the delay of the marker signals can be set
without restarting the marker and signal.
The delay can be defined by moving the setting mark.