Functional
Area
Brief Description Change in Load
FG
connec-
tions
Fast
GOOSE
Interaction between indi-
vidual function groups, for
example, between the
Line function group and
the Circuit-breaker func-
tion group
Fast GOOSE communica-
tion
Adding or removing
Protection functions and their stages
Circuit-breaker function groups
Fast GOOSE connections
Protection
Communica-
tion
Signal transmission via protec-
tion communication and differ-
ential protection communica-
tion
Adding or removing
Communication modules for the protection interface
(in the DIGSI 5 Hardware and logs view)
Routings to the protection interface
Function
Groups
Function Groups Adding or removing function groups such as:
FG V/I 3-phase
Overcurrent
protection
Overcurrent protection Adding or removing
Overcurrent protection, phases
Overcurrent protection, ground
Measuring
point super-
vising func-
tion, protec-
tion communi-
cation
Measuring-point supervi-
sion functions
Scope of the data trans-
mission via the protection
communication
Adding or removing measuring points or individual super-
vising functions, such as
3-phase current measuring point
3-phase voltage measuring point
Measuring-voltage failure detection
Add to or remove from transmission values via the protec-
tion communication
Single-point indications
Measured values
Other protec-
tion
Protection functions with low
requirements for fast operate
times
Adding or removing
Overload protection functions
Functions and stages of voltage protection
All functions not listed previously
CFC event-trig-
gered,
standard
GOOSE
CFC charts with a maximum
processing time of 40 ms
Adding or removing CFC charts in the event-triggered
process range
Create CFC chart
Delete CFC chart
Change the process range in the properties of the CFC
chart
Add to or remove from CFC charts in the event-triggered
process area
Control
Other
contin-
uous
function
chart
Opera-
tional
measured
values
Control and interlocking
CFC charts in the area of
control, measured-value
preprocessing, and event-
controlled
Operational measured
values
Adding or removing
Function blocks for control and interlocking
CFC charts in the control area
Switching devices (except circuit breakers), for
example, Disconnector function groups
Operational measured values
CFC charts in the measured values area
If the load model displays a warning, bear in mind the following general instructions:
Supervision Functions
9.2 Resource-Consumption Supervision
1240 SIPROTEC 5, Overcurrent Protection, Manual